ค้นหาสินค้า
บริการ
-
Multimeter
-
LCRMeter
-
Spectrum Analyzer
-
Oscilloscope
-
Vector Network Analyzer
-
Function generator
-
Audio Signal Generator
-
Frequency counter
-
RLC Dc Decade Resistance Box
-
Programmable electronic
-
Slide Voltage
-
Lab power supply
-
Clamp on meter
-
Power Analyser
-
Ultrasonic Flow Meter
-
Earth and Soil resistivity
-
Insulation tester
-
milliohm and microohm resistance tester
-
Impulse Winding Tester
-
Safety Tester/Hipot Tester
-
Tachometer Stoboscope
-
Vibration Meter
-
Anemometer
-
Sound meter
-
Lux meter
-
Water Quality Meter
-
Air Environment
-
Hygrometer Thermometer
-
Multifunction / Installation Tester
-
RF Spectrum Analyzer
-
Thermal Image camera
-
Infrared thermometer
-
EMF Spectrum Analyzer
-
Solar cell & Photovoltaic system
-
Calibrator
-
Battery Tester
-
High Voltage Hotline Tools
-
Miscellaneous Meter
-
Trainer Laboratory
-
Transformer Turns Ratio Meter
-
Insulation Oil Tester
-
Accessories
สมัครงาน
ลิ้งก์ภาพ
GA40XX Series : 1.5GHz/3GHz/7.5GHz สเปคตรัมอนาไลเซอร์
ข้อมูลสินค้า
-
รหัสสินค้า
GA40XX
-
เข้าชม
1,753 ครั้ง
ยี่ห้อ
ATTEN
รุ่น
GA40XX
-
แก้ไขล่าสุดเมื่อ
30/04/2019 15:50
-
รายละเอียดสินค้า
GA40XX Series : 1.5GHz/3GHz/7.5GHz Spectrum Analyzer
Features : ▪ Frequency range of 9 kHz to 1.5GHz/3GHz/7.5GHz ▪ Displayed average noise level (DANL) <-148 dbm="" td=""> ▪ -90 dBc/Hz, (Offset 10 kHz) ▪ Full amplitude accuracy <1.0 dB ▪ Minimum resolution bandwidth (RBW) 1 Hz ▪ Standard preamplifier ▪ Tracking Generator(Optional) ▪ Measurement capabilities and a variety of automatic settings ▪ 8.5-inch (800x480) widescreen display ▪ The interface is simple and rich in affinity, operation and has user-friendly design ▪ Compact portable design, weighing less than 7 kg ▪ Phase Noise -95 dBc/Hz, -100 dBc/Hz Specifications : Model No GA4062 GA4032 GA4033 GA4063 GA4064 Frequency Specifications Frequency range 9kHz~1.5GHz 9kHz~3GHz 9kHz~7.5GHz Internal 10 MHz frequency reference accuracy Initial calibration accuracy ±1×10 -7 Aging rate ±0.1ppm /year ±1ppm /year ±0.1ppm /year Temperature stability ± 5 × 10 -8 Referenced to frequency reading at 0-50 °C Frequency readout accuracy with marker (start, stop, center, marker) Marker resolution (frequency span)/(sweep points -1) Uncertainty ± (frequency indication × frequency reference uncertainty +1% × span +10% ×resolution bandwidth + marker resolution+1 Hz) Frequency reference uncertainty = (aging rate × period of time since adjustment + temperature stability) Marker frequency counter Resolution 1 Hz Accuracy ±(marker frequency × frequency reference uncertainty +counter resolution) (marker level to displayed noise level > 25 dB; frequency offset 0 Hz) Frequency span Range 0Hz (zero span), 100 Hz to 3GHz Resolution 1 Hz Accuracy ±span/(sweep points -1) SSB phase noise <-100 dBc ∕Hz@10kHz <-90dBc /Hz@10kHz <-95dBc/Hz@10kHz (Center frequency 500 MHZ, RBW=100Hz, VBW=1Hz 20 °C to 30 °C) Resolution bandwidth (RBW) -3 dB bandwidth 1 Hz ~ 3 MHz 100 Hz ~ 1 MHz 1 Hz ~ 3 MHz Accuracy ± 5%, RBW = 1Hz to 1 MHz Nominal, ±20%, RBW = 3 MHz Resolution filter shape factor < 5 : 1 Video bandwidth (VBW) -3 dB bandwidth 1 Hz to 3 MHz, 1-3-10 sequence Amplitude specifications : Measurement range +30dBm to displayed average noise level (DANL) Input attenuator range 0 dB to 50 dB, in 10 dB steps Maximum safe input level Average continuous power +30 dBm, (3 minutes maximum, Input attenuator≥20 dB, preamplifier off DC voltage 50V 25V Displayed average noise level Preamp on ≤- 148dBm ≤- 128dBm ≤- 148dBm -160dBm -140dBm -160dBm Preamp off ≤- 130dBm ≤- 110dBm ≤- 130dBm Model No GA4062 GA4032 GA4033 GA4063 GA4064 Amplitude specifications(Cont’d) Level display range Log scale 10 dB to 100 dB, 10 divisions displayed; 1, 2, 5, 10 dB/division Linear scale 0% to 100%, 10 divisions displayed Scale units dBm, dBmV, dBuV, dBuV/m, uV, mV, V, mW, W Sweep (trace) points 501 Marker level readout resolution Log scale 0.01 dB Linear scale ≤1% of signal level Nominal Detectors Normal, Positive peak, Sample, Negative peak Number of traces 3 Level display range Trace functions Clear/write, Maximum hold, Minimum hold, View Level measurement error ±(0.6 dB+frequency response ), all frequency Frequency response ±1 dB Reference level Setting range -110 dBm to +30 dBm steps of 1 dB Setting resolution Log scale 0.01 dB Linear scale Same as log (2.236 μV to 7.07 V) Accuracy 0 RF Input VSWR (at tuned frequency) < 1.5:1, (10 MHz to 3 GHz, 10 dB or 20 dB attenuation) Spurious response Second harmonic distortion < -70dBc, (Mixer signal level at -40 dBm, input attenuation 0 dB, preamp off) Third order intermodulation distortion < -70dBc,(Two -30 dBm tones at input mixer, spaced by 1MHz input attenuation 0 dB, preamp off) Input related spurious < -60dBc, (-30 dBm signal at input mixer) Inherent residual response <-88dBm, (Input terminated 50Ω and 0 dB RF attenuation, preamplifier off) Sweep specifications Sweep time Range 10ms to 3000s, Span≥100 Hz;100μs to 100s, Span = 0 Hz (zero span) Sweep mode Continuous, single Trigger source Free run, Line trigger, External trigger Trigger slope Positive or Negative edge available RF input Connector and impedance N-Type female, 50 Ω Nominal. 10 MHz reference Reference input frequency 10 MHz Reference input amplitude 0 dBm to +10 dBm Reference output frequency 10 MHz Reference output amplitude 0 dBm to +10 dBm Connector BNC female, 50 Ω Nominal Model No GA4062 GA4032 GA4033 GA4063 GA4064 Auto Measurement Functions Phase noise, Adjacent channel power, Occupied bandwidth. Third order intermodulation distortion, Pass/Fail, Standing wave ratio. Interface Host connector USB Type-A female Device connector USB Type-mini AB female, LAN, RS232 or VGA General specifications Display Resolution 800 pixels x 480 pixels Size and type 8.5 inch TFT color display Languages On-screen GUI: English, Simplified Chinese Power requirements Adaptor voltage 100 V to 240 V AC, Rate 50/60/400 Hz , Auto-ranging Power consumption less than 35W Environmental and size Temperature range 0 °C to +40 °C (Operating) -40 °C to +70 °C (Storage) Relative humidity < 95% Weight less than 7kg Dimensions 410 mm × 210mm × 136 mm, Approximately (W x H x D) Tracking generator (Optional) Frequency range 5MHz~1.5GHz 5MHz~3GHz 5MHz~7.5GHz Output level 0 dBm to -25 dBm, 1 dB steps Output flatness ± 3dB VSWR < 2.0: 1, Nominal Connector and impedance N-Type female, 50 Ω AM / FM Demodulation Measurement-except GA4032 (Optional) AM Demodulation Modulation Frequency 20Hz~100kHz Frequency Accuracy 1Hz(Modulation Frequency<1kHz) 0.1%(Modulation Frequency≥1kHz) Modulation Depth 5~95% Depth Measurement Precision ±4% FM Demodulation Modulation Frequency 20Hz~200kHz Frequency Accuracy 1Hz(Modulation Frequency<1kHz) 0.1%(Modulation Frequency≥1kHz) Frequency Offset 20Hz~400kHz Frequency Offset Precision ±4% SINAD Measurement Range 0~60dBc Measurement Precision ±1dB
Tags : สเปคตรัมอนาไลเซอร์ , เครื่องมือวัด , GA40XX , ATTEN , Spectrum Analyzer